Due to its concentration into gas, ozone needs efficient
and appropriate contact devices.
POROUS DIFFUSERS
The
diffusers are devices anchored to the bottom and made
from an ozone resistant porous material forming many
very fine gas bubbles. Diffusers are normally introduced
in the bottom of the contact chamber below water level.
EJECTORS
Ejector or
venturi systems can allow ozone to be introduced into
liquid media with a higher pressure than that available
in the ozone generator. It produces a flow containing
many fine bubbles depending on the operating pressure
and liquid/gas ratio.
SPECIAL PRESSURIZED CONTACTORS
Special reactors are designed to bring ozone into
contact with organic substrates or water that must
be oxidized with the aid of physical and chemical
additives. As examples O3/H2O2- O3/UV – O3/CATALYSER
– O3 and CATALIZED MEMBRANES.
IN LINE MIXERS
When the liquid media have a lower pressure than that
inside the ozone generator, ozone can be combined
with static mixers designed to mingle ozone in fine
bubbles with the liquid.
|